Nettuno machines are used in gastropubs, casual eateries and small chains nationwide. The engineer carries out the statutory PSSR examination, the front-end service and the water treatment on this model — a standalone examination is £265 + VAT, or £440 + VAT with the service included.

2 group Single boiler Written Scheme of Examination

Quick answer

Does a Casadio Nettuno need a PSSR examination?

Yes, if it operates in a workplace. It carries a single steam boiler with its own protective devices, which is the pressure system in scope. Steam is a relevant fluid under PSSR 2000 and steam systems are covered at any pressure and any volume, so the boiler must have a Written Scheme of Examination and be examined periodically by a competent person.

Examination only
£265
With service
£440
Call for a fixed price

The machine

Why the Nettuno matters to the Casadio owner

A highly reliable, cost-conscious workhorse popular with gastropubs and casual eateries.

In practice you will find it in gastropubs, casual eateries and small chains — which shapes what the examination looks like on site: how the machine is accessed, how long it can be offline, and how much scale it has accumulated.

On the day

  • The steam boiler is drained and inspected internally with an endoscope for scale, corrosion and weld condition.
  • The safety valve, anti-vac valve and fittings are checked and tested.
  • The pressure gauge is verified against our calibrated test gauge, not against itself.
  • A 2 group single boiler is one drain and one refill, comfortably inside the standard appointment window.
  • The Written Scheme of Examination names the vessel and the protective devices it covers.

Typical rates for this model

Standalone PSSR examination
£265
Service + PSSR bundle
£440
Certified safety valve, if it fails
£35 + VAT
Water filter, fitted on a visit
from £107
Grinder calibration & deep clean
£89
If it does not pass
Explained in writing

All prices exclude VAT. A single steam boiler with one set of protective devices to examine. We confirm the exact figure on the call.

Filters are fitted on site by an engineer and are not posted out. The filter price applies when ordered with a PSSR examination, service, call-out or water test; booked alone it is charged at the standard call-out.

What we see on this model

  • Gastropub sites often run one machine hard through lunch and dinner with no midday break — book the examination outside those windows.
  • Straightforward hydraulics make this one of the quicker examinations we carry out.
  • Casadio's traditional model (product page archived 2024): positive-displacement pump, Easy Steam whipping system, thermosiphonic groups, 2.4-inch display, optional Wi-Fi telemetry kit. Casadio's own site returns HTTP 500. No fault reports, error codes or service intervals were found, and boiler capacity/material are not published in the sources read.

Verified boiler data

What is actually inside this machine

Manufacturer boiler capacities for the Casadio Nettuno
ConfigurationSteam boiler
1 group 4.5 L
2 group compact 7.0 L
3 group 14.5 L

Manufacturer's published boiler capacities. Where a maker publishes no figure we say so rather than estimate.

Service interval. Not documented in the sources found.

Source: Casadio NETTUNO official brochure (Gruppo Cimbali, E-CASADIO-NETTUNO-BROCHURE-DIGITAL-EN-IT), 'Technical sheets / Schede tecniche', 1 GROUP column: WxDxH 457 x 523 x 527 mm; Weight 39 kg; Power 2.8-3.3 kW; BOILER CAPACITY 4.5 L. The Nettuno is a thermosyphon machine with a single boiler. The installation data sheet (rev.2438) additionally gives hydraulic feeding pressure 1-6 bar, which is mains water inlet pressure, not boiler design pressure.

Fault finder

What actually goes wrong on a Casadio Nettuno

Owners usually call us with a symptom, not a diagnosis. This is what that symptom most often turns out to be on this machine, and what putting it right involves.

Common faults on the Casadio Nettuno
SymptomUsual causeWhat fixes it
"Machine cold - wait" warning when a coffee key is pressed. The boiler has not reached its set working pressure and a delivery key was pressed. Wait for the boiler to reach pressure before dispensing.
Volumetric sensor error symbol in place of the group symbol, about 5 s into delivery; the shot continues. Interruption or fault in the volumetric sensor (flowmeter) - no pulses reaching the board. Casadio directs the user to the service centre; the technician checks the flowmeter, its connector and the board input.
Filling timeout - the machine faults and all keypad LEDs flash; no dispensing. The level probe stayed uncovered for 15 minutes: no water, fill circuit fault or a scaled/insulated probe. Service call: restore water, check the fill solenoid and clean/replace the level probe, then reset.
EasySteam error icon (flashing) instead of the normal EasySteam symbol. Defective thermocouple or no connection to the thermocouple interface; or the interface is faulty/not connected to the display board. Check the thermocouple and interface connections; replace the faulty thermocouple/interface.
Display connection error icon. Display plugged into the wrong connector on the mainboard, display not seated, or pins/crimps wrong (pins 2 and 3 not crossed). Reconnect the display to the white mainboard connector, reseat it and check the crimps/pin order.

These are faults documented for this model, not a generic list.

Common parts

Common parts for the Casadio Nettuno

The components most often replaced on this machine, listed by reference number, as a reference for engineers and owners identifying a part.

Common parts for the Casadio Nettuno
Part no.Description
#19251 Ptfe Element Gasket 58 X 50 X 2 Mm (For Jag30775 & Jag15876)
#2102 Parker 3 Way Grp Solenoid Valve 24v (Plus 3 housings in)
#2841 Element Protection Thermostat - Original
#0398 Lucifer 3 Way Grp Solenoid Valve 230v (Ruby)
#18281 Parker 3 Way Solenoid Valve 24v
#0450 PARKER 3 WAY GRP SOLENOID VALVE 230V (RUBY)
#23371 PARKER 2 WAY INLET SOLENOID VALVE 230V
#29950 PARKER 3 WAY SOLENOID VALVE 24V
#15876 Casadio 2grp Element 5400w - Original
#23615 Faema / Casadio Double Shower Plate 58 X 19mm
#30775 Casadio Undici Element 2700w L= 195mm
#18141 Group Seal 74 X 58 X 8MM

Parts most often needed on this model

Parts commonly needed by the Casadio Nettuno
PartNumberWhat it fixes
Double spout (short), Nettuno — Replacement for a damaged or missing spout (dealer lists it as a Nettuno part)
2-cup filter basket, Nettuno — Replacement for a worn or lost double basket (dealer lists it as a Nettuno part)
Group gasket 402199010 Group seal; first wear item on the thermosiphonic group.
Shower group (shower screen assembly) 457560000 Scales and deforms; replaced with the group gasket.
Complete level probe 959714000 Scale on the probe causes overfilling and the 15-minute filling timeout.
Pressurestat 532195500 Boiler pressure control; drift or burnt contacts gives weak/unstable steam.
Heating element, 220 V 5400 W, L=400 778505010F Main boiler element.
Safety valve, 1.9 bar, 1/4 G 532392500 Boiler safety valve; PSSR-relevant and replaced if it weeps or will not reseat.

Questions

Nettuno questions, answered

How a boiler of this size is examined, how often, and who carries the duty — see the complete PSSR guide.

0208 037 9340

How much does a PSSR examination cost on a Casadio Nettuno?

A standalone examination is £265 + VAT, because a single steam boiler with one set of protective devices to examine. Combined with a front-end service it is £440 + VAT, which is what most gastropubs, casual eateries and small chains choose, since the boiler has to be drained for the examination either way. We confirm the exact figure on the call.

How often does a Casadio Nettuno need examining?

The Written Scheme of Examination sets the interval, and for a commercial machine used in gastropubs, casual eateries and small chains it is typically 12 to 14 months. A single boiler on this duty normally sits at the middle of that range unless the water is hard, which we test on the day and report with the certificate.

How long does a Casadio Nettuno examination take, and what happens on the day?

A 2 group single boiler is one drain and one refill, comfortably inside the standard appointment window. The visit runs: the steam boiler is drained and inspected internally with an endoscope for scale, corrosion and weld condition. the safety valve, anti-vac valve and fittings are checked and tested. The gauge is then verified against our calibrated test gauge, the system is pressure tested and held, and the machine is re-assembled, refilled, heated and function tested. The Written Scheme of Examination, signed report and asset record follow within 48 hours.