Skip to content

Crem & Expobar · 2 and 3 group

Crem & Expobar Diamant Pro — PSSR examination & servicing

Diamant Pro machines are used in hotels, banqueting halls and high-volume catering nationwide. The engineer carries out the statutory PSSR examination, the front-end service and the water treatment on this model — a standalone examination is £295 + VAT, or £500 + VAT with the service included.

2 and 3 group Single boiler Written Scheme of Examination

Quick answer

Does a Crem & Expobar Diamant Pro need a PSSR examination?

Yes, if it operates in a workplace. It carries a single steam boiler with its own protective devices, which is the pressure system in scope. Steam is a relevant fluid under PSSR 2000 and steam systems are covered at any pressure and any volume, so the boiler must have a Written Scheme of Examination and be examined periodically by a competent person.

Examination only
£295
With service
£500
Call for a fixed price

The machine

Why the Diamant Pro matters to the Crem & Expobar owner

A robust commercial machine popular in high-volume hotels and banqueting halls.

In practice you will find it in hotels, banqueting halls and high-volume catering — which shapes what the examination looks like on site: how the machine is accessed, how long it can be offline, and how much scale it has accumulated.

On the day

  • The steam boiler is drained and inspected internally with an endoscope for scale, corrosion and weld condition.
  • The safety valve, anti-vac valve and fittings are checked and tested.
  • The pressure gauge is verified against our calibrated test gauge, not against itself.
  • A 3 group boiler holds more water than a 2 group, so the drain, refill and heat-up all take longer — allow the full appointment window.
  • The Written Scheme of Examination names the vessel and the protective devices it covers.

Typical rates for this model

Standalone PSSR examination
£295
Service + PSSR bundle
£500
Certified safety valve, if it fails
£35 + VAT
Water filter, fitted on a visit
from £107
Grinder calibration & deep clean
£89
If it does not pass
Explained in writing

All prices exclude VAT. The additional drain and heat-up time a 3 group boiler needs. We confirm the exact figure on the call.

Filters are fitted on site by an engineer and are not posted out. The filter price applies when ordered with a PSSR examination, service, call-out or water test; booked alone it is charged at the standard call-out.

What we see on this model

  • Banqueting machines run flat out for events and sit idle between them — idle periods are the ideal examination window.
  • High-volume catering should pair the statutory examination with a filter programme; scale is what shortens the life of these boilers.
  • Crem International (Gandia, Spain) builds Expobar and Crem from the same platform. Alarm wording above is the machine's own, from Crem's Diamant user manual (1764214_01). The GICAR control board is the other known failure point on this platform - when the display and buttons go dead the display head and the GICAR board are the two suspects.

Verified boiler data

What is actually inside this machine

Manufacturer boiler capacities for the Crem & Expobar Diamant Pro
ConfigurationSteam boiler
2 group 11.5 L
3 group 17.5 L

Manufacturer's published boiler capacities. Where a maker publishes no figure we say so rather than estimate.

Service interval. No fixed interval published - the machine raises a 'Service' alarm (counter) and a separate 'Filter' alarm for the water softener. Clean the drain cup regularly and maintain the softener; Crem's own manual attributes 90% of faults to limesc

Source: Crem (Expobar) Diamant Pro 2GR manufacturer product page, Technical Specifications table for 'Diamant Pro 2GR TA': W x D x H 88.5 cm x 62 cm x 53.5 cm; Boiler(s) capacity 11.5 l; Operation pressure 0.8 to 1.2 bar; Power Output 3600 Watts; 220-240 V. The same table publishes Weight as '180.8 lb / 53.5 kg', which is internally inconsistent (180.8 lb = 82.0 kg), so weight is returned as null - see suspect list. Only 'Operation pressure' is published, not a design or maximum pressure.

Fault finder

What actually goes wrong on a Crem & Expobar Diamant Pro

Owners usually call us with a symptom, not a diagnosis. This is what that symptom most often turns out to be on this machine, and what putting it right involves.

Common faults on the Crem & Expobar Diamant Pro
SymptomUsual causeWhat fixes it
Shots run cold or groups stop delivering water altogether, boiler and pipework feel scaled limescale in the heat-exchanger outlet pipes and the water system, usually a neglected softener descale or replace the affected HX pipework and group circuit, and restore proper water treatment.
Display and buttons dead or intermittent - the machine heats but will not respond failed display or GICAR control unit, on this machine the display head carries the group-boiler control logic replace the display/GICAR unit, and on multi-boiler versions check the group-boiler control side.
'Flowmeter X' alarm and the group will not dose, or the dose light flashes and nothing happens no pulses from that group's flowmeter - scale or debris in the meter, wiring, or a dead meter strip and clean or replace the flowmeter, check the plug and loom.
'Tprobe Unconnect' or a temperature-sensor alarm, boiler temperature control lost boiler temperature probe open circuit or disconnected - probe, plug or loom re-seat the probe connector, then replace the probe.
Water on the floor or in the base of the machine after service drain cup or tube blocked with grounds, or the drain tube has come off the cup clean the drain cup and tube, reconnect and re-route so it cannot kink.
Steam wand stops steaming although the boiler is up to pressure nozzle or tip clogged with dried milk remove the nozzle and unclog it with a pin, clean the wand.
'Flowmeter X Alarm' and that group will not dose. No water flow detected by flowmeter X - scale or debris in the meter, a stuck turbine, or a wiring/plug fault. Strip and clean or replace the flowmeter, check the plug and loom.
'Tprobe Unconnect' / temperature sensor warning; boiler temperature control lost. Temperature sensor not functioning: open-circuit probe, unseated connector or damaged lead. Re-seat the probe connector, then replace the probe.
'No Water' warning and the machine will not brew. The machine is not receiving water - mains, filter, or the inlet solenoid. Restore supply, clean the inlet filter, test/replace the inlet solenoid.
Cold shots, or groups stop delivering water; boiler and pipework feel scaled. Limescale in the heat-exchanger outlet pipes and water system - Crem states 90% of faults are limescaling from unsoftened water. Descale or replace the affected HX pipework, restore proper water treatment.
Water under the machine; steam wand stops steaming. Drain tube blocked or disconnected; steam nozzle clogged with dried milk. Clean/reconnect the drain cup and tube; unclog the nozzle with a pin and soak.

These are faults documented for this model, not a generic list.

Common parts

Common parts for the Crem & Expobar Diamant Pro

The components most often replaced on this machine, listed by reference number, as a reference for engineers and owners identifying a part.

Common parts for the Crem & Expobar Diamant Pro
Part no.Description
#2841 Element Protection Thermostat - Original
#23819 0230030043r - Rhea Product Chute Left - High - Original
#2102 Parker 3 Way Grp Solenoid Valve 24v (Plus 3 housings in)
#0398 Lucifer 3 Way Grp Solenoid Valve 230v (Ruby)
#18281 Parker 3 Way Solenoid Valve 24v
#0450 PARKER 3 WAY GRP SOLENOID VALVE 230V (RUBY)
#23371 PARKER 2 WAY INLET SOLENOID VALVE 230V
#29950 PARKER 3 WAY SOLENOID VALVE 24V
#0020 Pump Head Rotoflow
#0093 Sirai Pressure Switch
#1497 Parker Pressure Switch
#1578 Solenoid O Rings Bag Of 100

Parts most often needed on this model

Parts commonly needed by the Crem & Expobar Diamant Pro
PartNumberWhat it fixes
Diamant display 60101060 Display head carries the group/boiler control interface - dead or intermittent display and buttons.
Diamant touchpad 60101510 Membrane keypad; the other half of a dead front panel.
Flowmeter — 'Flowmeter X' alarm and no-dose - Crem lists the flowmeter as a discrete part but no Diamant number was found in the documents obtained.
Temperature probe (NTC) — 'Tprobe Unconnect' is a probe/connector failure.

Questions

Diamant Pro questions, answered

How a boiler of this size is examined, how often, and who carries the duty — see the complete PSSR guide.

0208 037 9340

How much does a PSSR examination cost on a Crem & Expobar Diamant Pro?

A standalone examination is £295 + VAT, because the additional drain and heat-up time a 3 group boiler needs. Combined with a front-end service it is £500 + VAT, which is what most hotels, banqueting halls and high-volume catering choose, since the boiler has to be drained for the examination either way. We confirm the exact figure on the call.

How often does a Crem & Expobar Diamant Pro need examining?

The Written Scheme of Examination sets the interval, and for a commercial machine used in hotels, banqueting halls and high-volume catering it is typically 12 to 14 months. A 3 group boiler holds a larger volume of water, so scale accumulates faster than in a smaller machine on the same duty and the scheme usually sets the shorter interval.

How long does a Crem & Expobar Diamant Pro examination take, and what happens on the day?

A 3 group boiler holds more water than a 2 group, so the drain, refill and heat-up all take longer — allow the full appointment window. The visit runs: the steam boiler is drained and inspected internally with an endoscope for scale, corrosion and weld condition. the safety valve, anti-vac valve and fittings are checked and tested. The gauge is then verified against our calibrated test gauge, the system is pressure tested and held, and the machine is re-assembled, refilled, heated and function tested. The Written Scheme of Examination, signed report and asset record follow within 48 hours.

Other Crem & Expobar machines covered

Call and we'll price your Diamant Pro on the spot.

Same-week appointments nationwide, the Written Scheme of Examination issued within 48 hours of the visit, and a fixed price agreed before we travel.