Conti Monte Carlo — PSSR examination & servicing

Monte Carlo machines are used in mid-sized independent specialty shops and small groups nationwide. The engineer carries out the statutory PSSR examination, the front-end service and the water treatment on this model — a standalone examination is £265 + VAT, or £440 + VAT with the service included.

2 group Single boiler Written Scheme of Examination

Quick answer

Does a Conti Monte Carlo need a PSSR examination?

Yes, if it operates in a workplace. It carries a single steam boiler with its own protective devices, which is the pressure system in scope. Steam is a relevant fluid under PSSR 2000 and steam systems are covered at any pressure and any volume, so the boiler must have a Written Scheme of Examination and be examined periodically by a competent person.

Examination only
£265
With service
£440
Call for a fixed price

The machine

Why the Monte Carlo matters to the Conti owner

A traditional machine used by mid-sized independent specialty coffee shops.

In practice you will find it in mid-sized independent specialty shops and small groups — which shapes what the examination looks like on site: how the machine is accessed, how long it can be offline, and how much scale it has accumulated.

On the day

  • The steam boiler is drained and inspected internally with an endoscope for scale, corrosion and weld condition.
  • The safety valve, anti-vac valve and fittings are checked and tested.
  • The pressure gauge is verified against our calibrated test gauge, not against itself.
  • A 2 group single boiler is one drain and one refill, comfortably inside the standard appointment window.
  • The Written Scheme of Examination names the vessel and the protective devices it covers.

Typical rates for this model

Standalone PSSR examination
£265
Service + PSSR bundle
£440
Certified safety valve, if it fails
£35 + VAT
Water filter, fitted on a visit
from £107
Grinder calibration & deep clean
£89
If it does not pass
Explained in writing

All prices exclude VAT. A single steam boiler with one set of protective devices to examine. We confirm the exact figure on the call.

Filters are fitted on site by an engineer and are not posted out. The filter price applies when ordered with a PSSR examination, service, call-out or water test; booked alone it is charged at the standard call-out.

What we see on this model

  • The steam boiler and its protective devices are what the examination covers, and the visit length follows boiler volume and group count.
  • 2 group: 10 L steam boiler (6.5 L hot water, 3.5 L steam) and 2 x 0.9 L coffee boilers; 3 group: 14 L and 3 x 0.9 L. 89 kg / 103 kg empty. Three-phase machine; can run single-phase 230 V with power management steps 1-6 (2G 1900-6700 W, 3G 2600-9600 W; K variants up to 14100 W) and a 3x6 mm cable, Conti ref 103600. Coffee boiler elements 1000 W (2500 W on K).

Verified boiler data

What is actually inside this machine

Manufacturer boiler capacities for the Conti Monte Carlo
ConfigurationSteam boiler
2 group 10.0 L
3 group 14.0 L

Manufacturer's published boiler capacities. Where a maker publishes no figure we say so rather than estimate.

Service interval. Daily: automatic group clean from the display (blind filter + Conti pill 466662), steam and hot water outlets cleaned, at least 2 L hot water drawn. Half-year: kit 450200 - new filter gasket 002711 and sprinkler 415684 per group, descale le

Source: Conti Monaco Monte Carlo Product Sheet (manufacturer PDF), '2 Group' column. Published figures: Height 554 mm, Width 896 mm, Depth 612 mm, Weight 86 kg, Steam Boiler Size 10 Litres, Coffee Boiler Size 0.9 x 2 (i.e. 0.9 litre per coffee group), Group Element 100 W, Steam Boiler Element 4200/6000 W, Coffee Boiler Element 1000/2500 W, Total Power 1900-6700/3000-11500 W (power-managed), Voltage 400 V (230 V option). No design or maximum pressure is stated.

Fault finder

What actually goes wrong on a Conti Monte Carlo

Owners usually call us with a symptom, not a diagnosis. This is what that symptom most often turns out to be on this machine, and what putting it right involves.

Common faults on the Conti Monte Carlo
SymptomUsual causeWhat fixes it
A t-degree alarm on the display identifying a boiler or group numbered alarm table A01-A29 includes per-boiler and per-group temperature probe alarms identify the numbered probe from the table and replace that probe.
Heating stops, low-level safety alarm (A22) low-level safety probe detected no water for more than 2 seconds, so heating is stopped restore water/level, then check the safety probe.
Boiler will not reach heat, A23 boiler heat time-out element, contactor/SSR, or probe, test the heating chain.
A group stops, flow-meter time-out alarms A27/A28/A29 flow meter time-out after more than 5 seconds, Conti's own note says 'check for clogged coffee group' check the group for a blockage and the flowmeter.
Scheduled service kits 450200 (half-year) and 450201 (annual, including the flow-meter non-return valve 415167) fit the kit at the stated interval.
A boiler probe alarm; one coffee boiler reads wrong or heating is inhibited. A01 / A03 / A05 - coffee boiler 1/2/3 temperature probe short-circuit or disconnected. Check the probe, its connection, then the electronic board.
Heating stops with a low-level alarm (A22). The low-level safety probe detected no water for more than 2 s, so boiler heating is stopped. Restore water and confirm the boiler fills, then check the safety probe (and descale it) and the board.
Boiler never reaches temperature; A23 boiler time-out. Time allocated to boiler heating exceeded - water inlet, boiler probe, probe connection, board, heaters or relays, or the programmed heating time. Work the list: inlet, probe, element and relay; check the heating-time setting last.
Coffee stops mid-shot; A27 / A28 / A29 flowmeter time-out. No pulse from flowmeter 1/2/3 within 5 s - flowmeter, its connection, the board, or a clogged coffee group. Check flowmeter pulses and connection, then look for a blocked group.
One group runs cold or reads oddly; A09 / A11 / A13. Group 1/2/3 temperature probe short-circuit or disconnected. Check that group's probe and connection, then the board.

These are faults documented for this model, not a generic list.

Common parts

Common parts for the Conti Monte Carlo

The components most often replaced on this machine, listed by reference number, as a reference for engineers and owners identifying a part.

Common parts for the Conti Monte Carlo
Part no.Description
#2102 Parker 3 Way Grp Solenoid Valve 24v (Plus 3 housings in)
#2841 Element Protection Thermostat - Original
#0398 Lucifer 3 Way Grp Solenoid Valve 230v (Ruby)
#18281 Parker 3 Way Solenoid Valve 24v
#0450 PARKER 3 WAY GRP SOLENOID VALVE 230V (RUBY)
#23371 PARKER 2 WAY INLET SOLENOID VALVE 230V
#29950 PARKER 3 WAY SOLENOID VALVE 24V
#0020 Pump Head Rotoflow
#0093 Sirai Pressure Switch
#1497 Parker Pressure Switch
#1578 Solenoid O Rings Bag Of 100
#1586 Shower Plate 52 X 5mm

Parts most often needed on this model

Parts commonly needed by the Conti Monte Carlo
PartNumberWhat it fixes
Half-year kit 450200 Group gasket 002711 + sprinkler 415684 and sensor clean
Annual/biennial kit 450201 Full hydraulic service set
Safety valve (steam boiler) 411827 Annual replacement; PSSR item
Pump inlet filter 411861 Annual replacement
12-bar limiter 409774 Biennial; coffee boiler and inlet block over-pressure
Inlet boiler valve 470161 Biennial replacement

Questions

Monte Carlo questions, answered

How a boiler of this size is examined, how often, and who carries the duty — see the complete PSSR guide.

0208 037 9340

How much does a PSSR examination cost on a Conti Monte Carlo?

A standalone examination is £265 + VAT, because a single steam boiler with one set of protective devices to examine. Combined with a front-end service it is £440 + VAT, which is what most mid-sized independent specialty shops and small groups choose, since the boiler has to be drained for the examination either way. We confirm the exact figure on the call.

How often does a Conti Monte Carlo need examining?

The Written Scheme of Examination sets the interval, and for a commercial machine used in mid-sized independent specialty shops and small groups it is typically 12 to 14 months. A single boiler on this duty normally sits at the middle of that range unless the water is hard, which we test on the day and report with the certificate.

How long does a Conti Monte Carlo examination take, and what happens on the day?

A 2 group single boiler is one drain and one refill, comfortably inside the standard appointment window. The visit runs: the steam boiler is drained and inspected internally with an endoscope for scale, corrosion and weld condition. the safety valve, anti-vac valve and fittings are checked and tested. The gauge is then verified against our calibrated test gauge, the system is pressure tested and held, and the machine is re-assembled, refilled, heated and function tested. The Written Scheme of Examination, signed report and asset record follow within 48 hours.

Other Conti machines covered

Call and we'll price your Monte Carlo on the spot.

Same-week appointments nationwide, the Written Scheme of Examination issued within 48 hours of the visit, and a fixed price agreed before we travel.