Skip to content

Eversys · bean to cup

Eversys E4m — PSSR examination & servicing

E4m machines are used in sites that need E4 throughput in a narrower footprint nationwide. The engineer carries out the statutory PSSR examination, the front-end service and the water treatment on this model — a standalone examination is £265 + VAT, or £645 + VAT with the service included.

bean to cup Single boiler Written Scheme of Examination

Quick answer

Does a Eversys E4m need a PSSR examination?

Yes, if it operates in a workplace. It carries a single steam boiler with its own protective devices, which is the pressure system in scope. Steam is a relevant fluid under PSSR 2000 and steam systems are covered at any pressure and any volume, so the boiler must have a Written Scheme of Examination and be examined periodically by a competent person.

Examination only
£265
With service
£645
Call for a fixed price

The machine

Why the E4m matters to the Eversys owner

The slimmed E4, sharing its 5.6 litre sealed boiler with the E2m but running the larger brew platform.

In practice you will find it in sites that need E4 throughput in a narrower footprint — which shapes what the examination looks like on site: how the machine is accessed, how long it can be offline, and how much scale it has accumulated.

On the day

  • The steam boiler is located and examined. On a sealed stainless vessel the examination is external — wall thickness, corrosion at fittings, and the condition of every connection — with internal inspection by borescope only where the vessel design allows access.
  • The safety valve, expansion valve, pressure sensor and thermal cut-outs are identified, checked and function tested.
  • The pressure gauge is verified against our calibrated test gauge, not against itself.
  • The vessel is small and sealed, so there is no drain-down and refill to wait for. The time goes on getting to it, which is why the brew unit and panels come off.
  • The Written Scheme of Examination records the vessel as sealed and sets out the external examination and the protective devices it relies on.

Typical rates for this model

Standalone PSSR examination
£265
Service + PSSR bundle
£645
Certified safety valve, if it fails
Quoted per machine
Water filter, fitted on a visit
from £107
Grinder calibration & deep clean
£89
If it does not pass
Explained in writing

All prices exclude VAT. A single steam boiler with one set of protective devices to examine. We confirm the exact figure on the call.

Filters are fitted on site by an engineer and are not posted out. The filter price applies when ordered with a PSSR examination, service, call-out or water test; booked alone it is charged at the standard call-out.

What we see on this model

  • Same 5.6 litre vessel as the E2m at the same 3.3 bar rating, so the vessel examination is identical and only the service access differs.
  • Worth confirming on the data plate: E2m and E4m are easily confused on a site visit, and the record should name the right one.
  • Eversys parts are proprietary and dealer-supplied. The safety valve is a three-part rebuild kit rather than a valve you can buy off the shelf, and the annual parts kit runs into several hundred pounds. We quote those separately, before fitting.
  • Two groups plus milk; 5.6 L milk/steam boiler, available as an assembly (104343, e'4m V2). Both milk circuits carry their own pump, heater and temperature sensors, so a single bad side is a side-specific pump, nozzle or sensor rather than a shared fault. Same 12-month brew/milk and 24-month grinder/hydraulic kit rhythm as the E4.
  • A standalone Eversys preventative maintenance visit runs £300–£600 on the open market for labour plus the mandatory manufacturer kit, and an inclusive contract £1,000–£2,200 a year. Our published bundle covers the labour and the examination; the Eversys service kit itself is charged at cost with the visit, because kit prices move with the model and the cycle count. Eversys build the machine from removable modules, so a module swap is quick work compared with stripping a traditional group.

Verified boiler data

What is actually inside this machine

Manufacturer boiler capacities for the Eversys E4m
ConfigurationSteam boiler
e'4m Eline (2 coffee boilers) 5.6 L

Manufacturer's published boiler capacities. Where a maker publishes no figure we say so rather than estimate. Field median 5.6 litres, matching the manufacturer figure.

Service interval. Eversys E-line service kits are scheduled by cycles and time together. Brew, steam and milk kits are 12-month items; grinder, hydraulic and frame kits are 24-month items; each kit is sized for 100,000 cycles (Eversys e'Support kit tables).

What a service covers

  • ›Brew unit module cleaned and its 12-month kit fitted
  • ›Grinder checked and recalibrated; burrs assessed against wear limits
  • ›Steam and milk modules serviced on their own 12-month kits
  • ›Water filter renewed and the boiler safety devices and pressure checked
  • ›Firmware and telemetry reviewed remotely before the visit where the machine reports

Source: Eversys e'4m data sheet (Eline)

Fault finder

What actually goes wrong on a Eversys E4m

Owners usually call us with a symptom, not a diagnosis. This is what that symptom most often turns out to be on this machine, and what putting it right involves.

Common faults on the Eversys E4m
SymptomUsual causeWhat fixes it
Machine halts mid-service, 'brewing unit blocked' / brew unit will not initialise (W-011, W-012, S-020) coffee and oil build-up plus worn top/bottom piston rod seals make the brew piston too stiff for the motor to home strip and clean the brew unit, fit the piston-rod fitting and o-rings from the brew PM kit, re-initialise.
Drinks run slow, 'water flow too low' (W-004/W-005) Eversys' own order: water supply, grinder set too fine, overloaded powder chute, then an exhausted water filter, scale at the flowmeter gives the same reading check supply and filter counter first, then grind, then hydraulic side.
No steam or milk, coffee still pours, E-102/E-103 fill timeout or E-104 heating timeout closed supply, blocked filter, failed inlet valve, scaled filling line, E-106/E-107 are sensor or stuck contactor instead supply and inlet valve for the timeouts, sensor and cable for E-107, element circuit and contactor for the overheat pair.
Grinder runs on and machine shuts down (E-021), or 'grinder blocked' (W-068/W-069) three causes Eversys separates: grind too fine, stone in the burrs, or a failed triac on the power board coarser grind and clear the obstruction, if E-021 is logged the power board triac is the suspect, not the grinder.
Machine refuses all coffee until cleaned (S-017) cleaning-ball dispenser light barrier dirty, or ball blocked/broken, so the machine believes it was cleaned without detergent and locks out refill or replace balls, clean the light barrier, complete a clean with a ball detected.
Time and date lost at every power cycle (W-027/W-028) display battery dead replace the display.
One side dead, other still serving e'4 has two independent brew modules and two displays, E-096/E-097/E-098 are display machine-type or software mismatch between the two match machine type and software across both displays.
Grinder runs on endlessly and the machine shuts down (E-021). Grinder motor detected turning endlessly; defective power-board triac is the documented cause. Replace the power-board triac (100 253).
'Timeout during steam boiler filling' (E-103) - no steam or hot water, coffee still works. Fill timeout: closed tap, blocked fill nozzle (exhausted water filter), or supply fault. Supply, filter, then fill nozzle.
Steam boiler overheats and the machine drops to standby (E-106). Eversys points at the steam boiler triac when the boiler overheats. Check/replace the steam boiler triac; confirm the pressure sensor reads sensibly (E-107 is its failure code).
Milk temperature too high on one or both sides (W-045 / W-046). Clogged nozzle after the milk pump, blocked or perished suction tube, or clogged pump/valve block; worsened by cleaning without Everclean. Everclean clean, clear the nozzle, replace the suction tube, check pump and valve block.
Milk pump not running (W-054 / W-055). Milk pump failure or wiring connection. Check pump and connector; replace the pump (101 332).

These are faults documented for this model, not a generic list.

Fault codes

Eversys error and message codes

The codes this range can display, transcribed from the manufacturer's error table. If the machine is showing one, the code names the system at fault before any strip-down.

Eversys error and message codes
CodeMeaning
E-000 Bean hopper rear missing
E-001 Bean hopper front missing
E-010 Software too old.
E-011 Please download the newest
E-012 Please download the newest
E-013 The software is too old for
E-014 Grinder unit not connected.
E-095 Software update running.
E-096 Right display deactivated
E-097 Please set machine type
E-098 Please start software update
E-099 Communication Error.
E-100 Pressure Sensor Always Zero
E-102 Steam Boiler Empty Timeout
E-103 Timeout during steam boiler
E-104 Timeout Steam Heating
E-105 Steam boiler connector
E-196 Right display deactivated
E-197 Please set machine type
E-198 Please start software update
E-199 Communication Error Steam
S-000 Initialize, please wait...
S-001 Coffee boiler is heating...
S-002 Bean hopper rear missing
S-003 Bean hopper front missing
S-004 Please empty the grounds
S-005 - Risk of injury!
S-006 Grounds drawer is full
S-007 Please insert grounds drawer
S-008 Please insert the grounds
S-009 Grounds drawer missing
S-010 Bean hopper front is empty
S-011 Bean hopper rear is empty
S-012 Bean hopper is empty or
S-013 Coffee quantity too high
S-014 Rinse necessary.
S-015 Check cleaning ball
S-016 The coffee machine has
S-017 Cleaning necessary.
S-018 The last cleaning hasn't
S-020 Brewing unit failure.
S-021 Grounds bin is full.
S-022 Coffee quantity too high
S-023 Cleaning required. Please
S-024 - Clean the milk tubes with a
S-025 Please wait...
S-026 1) Remove the milk tank
S-027 Interface not detected. All
S-028 The milk system has been
S-029 Milk fridge door open.
S-030 Source water tank empty.
S-031 Waste water tank full.
S-032 Milk unit not connected.
S-033 switched off.
S-034 Bean hopper left is empty or
S-035 Bean hopper right is empty
S-036 Have you refilled the source
S-037 Have you emptied the waste Have you emptied the waste
S-038 - Please empty waste water
S-100 Steam boiler is heating...
S-101 Please switch off the
S-102 Empty steam boiler...
S-103 Depressurize steam boiler...
S-104 Fill steam boiler...
S-105 Rinse necessary.
S-106 Initialize, please wait...
S-107 Steam boiler security probe
S-108 Interface not detected. All
S-109 Display open.
W-002 Coffee boiler left is heating...
W-003 Coffee boiler right is
W-004 Water flow left too low
W-005 Water flow right too low
W-006 Check cleaning ball
W-007 The coffee machine has
W-008 Press "Continue" to start the Press and hold the rinse key
W-009 Press "Continue" to start the Press and hold the rinse key
W-010 Invalid coffee recipe
W-011 Brewing unit initialization
W-012 Brewing unit initialization
W-013 Service necessary. Please
W-014 Please change the water
W-017 No grinder turns detected
W-018 Milk tank empty.
W-019 Steam pressure too low for
W-020 Top piston failure left.
W-021 Top piston failure right.
W-022 Bottom piston failure left.
W-023 Bottom piston failure right.
W-024 Milk tank empty.
W-025 No grinder turns detected
W-027 Date and time incorrect.
W-028 Date and time incorrect.
W-029 Failure of external EEPROM
W-030 Failure during backup to
W-034 No coffee powder detected
W-035 No coffee powder detected
W-036 Push brew chamber back
W-037 The milk system was
W-038 Coffee boiler temperature
W-039 Coffee boiler temperature
W-040 Milk heater temperature
W-041 Milk heater temperature
W-045 Milk temperature too high
W-046 Please check the milk
W-048 During the weekend all milk
W-049 The left milk temperature
W-050 Fan Front doesn't run.
W-051 Check if the front fan is
W-052 Fan of right grinder (hopper
W-053 The right milk temperature
W-054 Milk pump left doesn't run.
W-055 Milk pump right doesn't run.
W-056 Milk input temperature
W-057 Milk input temperature
W-058 Milk tank temperature left
W-059 Milk tank temperature right
W-060 Milk unit not connected.
W-061 The desired number of ticks
W-062 The desired number of ticks
W-063 The grinder has been
W-064 The grinder has been
W-065 Please schedule next service
W-066 Please schedule water filter
W-067 The extraction time is
W-068 The left grinder is blocked.
W-069 The right grinder is blocked.
W-070 Milk temperature too low
W-071 Milk temperature too low
W-072 The flow rate of left and
W-073 The flow rate during rinse
W-074 The flow rate during rinse
W-075 The extraction time left is
W-076 The extraction time right is
W-077 The flow rate during rinse
W-078 The flow rate during rinse
W-079 The coffee nozzle was not
W-080 The flow rate during rinse is
W-081 The right grinder could not
W-082 Water pump doesn't run.
W-083 Coffee boiler outlet
W-084 Bean level left too low.
W-085 Bean level right too low.
W-086 Initial rinse of milk system
W-088 Top piston zero position
W-099 Top piston zero position
W-101 Steam boiler pressure too
W-103 Steam wand left
W-104 Steam wand right

Transcribed from the Eversys error table supplied with the engineer documentation. Codes vary by software version.

Common parts

Common parts for the Eversys E4m

The components most often replaced on this machine, listed by reference number, as a reference for engineers and owners identifying a part.

Common parts for the Eversys E4m
Part no.Description
#2102 Parker 3 Way Grp Solenoid Valve 24v (Plus 3 housings in)
#2841 Element Protection Thermostat - Original
#0398 Lucifer 3 Way Grp Solenoid Valve 230v (Ruby)
#18281 Parker 3 Way Solenoid Valve 24v
#0450 PARKER 3 WAY GRP SOLENOID VALVE 230V (RUBY)
#23371 PARKER 2 WAY INLET SOLENOID VALVE 230V
#29950 PARKER 3 WAY SOLENOID VALVE 24V
— Element Gasket
— Milk Pump Oring Sml
— Milk Pump Oring Lrg
— Flowmeter O-Ring
— safety valve fitting

Parts most often needed on this model

Parts commonly needed by the Eversys E4m
PartNumberWhat it fixes
Triac 25 A, 800 VAC 100 253 E-021 grinder runaway; steam boiler triac for E-106
V2 e4m milk/steam boiler module 104343 Scaled/corroded 5.6 L milk/steam vessel - module exchange
Nozzle milk pump 101 663 W-045/W-046 milk temperature faults
Gear pump with EC motor (milk) 101 332 W-054/W-055 milk pump not running
Brewing unit E'4 - coffee 108473 Piston faults W-020 to W-023
Kit grinder burrs Drive Ø64 - left / right 103 340 / 103 341 Twin grinder burr wear

Questions

E4m questions, answered

How a boiler of this size is examined, how often, and who carries the duty — see the complete PSSR guide.

0208 037 9340

How much does a PSSR examination cost on a Eversys E4m?

A standalone examination is £265 + VAT, because a single steam boiler with one set of protective devices to examine. Combined with a front-end service it is £645 + VAT, which is what most sites that need E4 throughput in a narrower footprint choose, since the boiler has to be drained for the examination either way. The bundle on this range is higher than our standard ladder because its service parts are proprietary: a manufacturer service kit and an OEM safety valve cost several times the generic equivalents, and on some models there is no generic equivalent at all. We confirm the exact figure on the call.

How often does a Eversys E4m need examining?

The Written Scheme of Examination sets the interval, and for a commercial machine used in sites that need E4 throughput in a narrower footprint it is typically 12 to 14 months. A single boiler on this duty normally sits at the middle of that range unless the water is hard, which we test on the day and report with the certificate.

How long does a Eversys E4m examination take, and what happens on the day?

The vessel is small and sealed, so there is no drain-down and refill to wait for. The time goes on getting to it, which is why the brew unit and panels come off. The visit runs: the steam boiler is located and examined. on a sealed stainless vessel the examination is external — wall thickness, corrosion at fittings, and the condition of every connection — with internal inspection by borescope only where the vessel design allows access. the safety valve, expansion valve, pressure sensor and thermal cut-outs are identified, checked and function tested. The gauge is then verified against our calibrated test gauge, the system is pressure tested and held, and the machine is re-assembled, refilled, heated and function tested. The Written Scheme of Examination, signed report and asset record follow within 48 hours.

Other Eversys machines covered

Call and we'll price your E4m on the spot.

Same-week appointments nationwide, the Written Scheme of Examination issued within 48 hours of the visit, and a fixed price agreed before we travel.